konduktometr Portavo 902 Cond/904 Cond/904 X Cond
Conductivity meter Portavo 902 Cond/904 Cond/904 X Cond, Type 902 Cond
Výrobce
Zařazeno v kategoriích
Přenosné konduktometry
Popis
Conductivity meter Portavo 902 Cond/904 Cond/904 X Cond
Portavo 902 Cond
-The basic version for mobile conductivity measurement
-Robust, intuitive portable device for routine daily measurements in laboratories and processes
-A sensor quiver protects the sensor from drying out or being damaged in daily use
-The high-performance polymer housing ensures low water absorption and high impact resistance
-Over 1,000 hours of measurement with a single set of batteries (4x AA)
-Memosens sensors and analog sensors can be used on the same device
-The mineral glass display is perfectly readable even after years
Portavo 904 Cond
as Portavo 902 Cond, additionally with:
-Li-ion battery
-Data logger with 5,000 values
-Micro USB port and Paraly SW 112 software
Portavo 904 X Cond
as Portavo 904 Cond, additionally with:
-Conductivity measurement with ATEX approval for measurements up to Zone 0/1. Ideal for applications in the process industry. For the first time, Portavo enables direct on-site testing of process measuring points.
-The new MemoLog function allows the user to log calibration data from various Memosens measuring points
Specifications
Measuring range (Accuracy): 0.001µS/cm (c<0.05cm-1)
0.01µS/cm (c=0.05 to 0.2cm-1)
0.1µS/cm (c> 0.2cm-1)
TDS:
Salinity: 0 to 1999mg/l
0.0 to 45.0g/kg
Resistivity:
Concentration: 00.00 to 99.99MΩ x cm
0.00 to 9.99 (w/w) %
Conductivity input, analog: Multi-contact for 2-/4-electrode sensors with integrated temp detector
Measuring ranges
Sensor SE 202:
Sensor SE 204:
0.01 to 200μS/cm
1μS/cm to 500mS/cm
2-electrode sensors:
4-electrode sensors: 0.1μS x c to 200mS x c
0.1μS x c to 1000mS x c
Temperature input: 2 x 4mm diam. for integrated or separate temperature detector
Messbereich mit NTC 30 kΩ:
Messbereich mit Pt 1000: -20 to +120°C
-40 to +250°C
Conductivity input, Memosens: M8 socket, 4 pins, for Memosens lab cable
Measuring range sensor SE 215 MS: 10μS/cm to 20mS/cm
Conductivity input:
Temperature compensation: linear 0 to 20%/K, reference temperature adjustable
nLF: 0 to 120°C
Power supply:
Protection class acc. to DIN EN 60529: 4 x AA
IP66/67 with pressure compensation
Type 902 Cond
Portavo 902 Cond
-The basic version for mobile conductivity measurement
-Robust, intuitive portable device for routine daily measurements in laboratories and processes
-A sensor quiver protects the sensor from drying out or being damaged in daily use
-The high-performance polymer housing ensures low water absorption and high impact resistance
-Over 1,000 hours of measurement with a single set of batteries (4x AA)
-Memosens sensors and analog sensors can be used on the same device
-The mineral glass display is perfectly readable even after years
Portavo 904 Cond
as Portavo 902 Cond, additionally with:
-Li-ion battery
-Data logger with 5,000 values
-Micro USB port and Paraly SW 112 software
Portavo 904 X Cond
as Portavo 904 Cond, additionally with:
-Conductivity measurement with ATEX approval for measurements up to Zone 0/1. Ideal for applications in the process industry. For the first time, Portavo enables direct on-site testing of process measuring points.
-The new MemoLog function allows the user to log calibration data from various Memosens measuring points
Specifications
Measuring range (Accuracy): 0.001µS/cm (c<0.05cm-1)
0.01µS/cm (c=0.05 to 0.2cm-1)
0.1µS/cm (c> 0.2cm-1)
TDS:
Salinity: 0 to 1999mg/l
0.0 to 45.0g/kg
Resistivity:
Concentration: 00.00 to 99.99MΩ x cm
0.00 to 9.99 (w/w) %
Conductivity input, analog: Multi-contact for 2-/4-electrode sensors with integrated temp detector
Measuring ranges
Sensor SE 202:
Sensor SE 204:
0.01 to 200μS/cm
1μS/cm to 500mS/cm
2-electrode sensors:
4-electrode sensors: 0.1μS x c to 200mS x c
0.1μS x c to 1000mS x c
Temperature input: 2 x 4mm diam. for integrated or separate temperature detector
Messbereich mit NTC 30 kΩ:
Messbereich mit Pt 1000: -20 to +120°C
-40 to +250°C
Conductivity input, Memosens: M8 socket, 4 pins, for Memosens lab cable
Measuring range sensor SE 215 MS: 10μS/cm to 20mS/cm
Conductivity input:
Temperature compensation: linear 0 to 20%/K, reference temperature adjustable
nLF: 0 to 120°C
Power supply:
Protection class acc. to DIN EN 60529: 4 x AA
IP66/67 with pressure compensation
Type 902 Cond
Varianty produktu
Pro zobrazení cen na míru se přihlašte do klientské sekce.
Kód produktu
Kód produktu
Kód BDL 9774712 Kód výrobce 904 COND


Kód BDL 9774710 Kód výrobce
902 COND
Type 902 Cond
902 COND


Kód BDL 9774715 Kód výrobce
904 X COND
Type 904 X Cond
904 X COND


Máte otázky? Kontaktujte nás
Poslat