Dual infračervený teploměr TFI 550 s NiCr-Ni Connection
Dual Infrared Thermometer TFI 550 with NiCr-Ni Connection, Type TFI 550 , Description Dual Infrared Thermometer (without probe)
Výrobce
Zařazeno v kategoriích
Elektronické teploměry
Popis
Dual Infrared Thermometer TFI 550 with NiCr-Ni Connection
Addtional connection for NiCr-Ni temperature probes with SMP-connection.
Please order probes separately.
-Optics D:S = 30:1
-Dual laser
-NiCr-Ni connection for core temperature measurement with penetration probe
-Alarm when Min/Max exceeded
-Factory calibration certificate
Specifications:
Measurement range: -60 °C to +550 °C (-76 °F to 1022 °F)
Accuracy: ±2 °C at -18 °C to +23 °C
(±3.6 °F at 0 °F to 73 °F)
±1 % of measurement
±1 °C (whichever is larger) at +23 °C to +510 C
±1.8 °F (whichever is larger) at 73 °F to 950 °F
Resolution: 0.1 °C at -9.9 °C to +199 °C, otherwise 1 °C
(0.2 °F at 14 °F to 391 °F, otherwise 1.8 °F)
Response time (t99): Approximately 1 s
Emissivity factor: 0.1 to 1.0
Distance : spot ratio: 30:1
NiCr-Ni probe measurement:
Measurement range: -64 °C to +1400 °C (-83 °F to 2552 °F)
Connection: SMP
Accuracy: ±1 % of measurement value / ±1 °C (±1.8 °F),
whichever is larger
Battery:
Battery lifetime: 2 x AAA (Micro)
Typically 180 hours
Operating temperature:
Storage temperature: 0 °C to +50 °C (32 °F to 122 °F)
-20° C to +65 °C (-4 °F to 149 °F)
IP code: IP 20
Weight: approx. 180g
Type TFI 550
Description Dual Infrared Thermometer (without probe)
Addtional connection for NiCr-Ni temperature probes with SMP-connection.
Please order probes separately.
-Optics D:S = 30:1
-Dual laser
-NiCr-Ni connection for core temperature measurement with penetration probe
-Alarm when Min/Max exceeded
-Factory calibration certificate
Specifications:
Measurement range: -60 °C to +550 °C (-76 °F to 1022 °F)
Accuracy: ±2 °C at -18 °C to +23 °C
(±3.6 °F at 0 °F to 73 °F)
±1 % of measurement
±1 °C (whichever is larger) at +23 °C to +510 C
±1.8 °F (whichever is larger) at 73 °F to 950 °F
Resolution: 0.1 °C at -9.9 °C to +199 °C, otherwise 1 °C
(0.2 °F at 14 °F to 391 °F, otherwise 1.8 °F)
Response time (t99): Approximately 1 s
Emissivity factor: 0.1 to 1.0
Distance : spot ratio: 30:1
NiCr-Ni probe measurement:
Measurement range: -64 °C to +1400 °C (-83 °F to 2552 °F)
Connection: SMP
Accuracy: ±1 % of measurement value / ±1 °C (±1.8 °F),
whichever is larger
Battery:
Battery lifetime: 2 x AAA (Micro)
Typically 180 hours
Operating temperature:
Storage temperature: 0 °C to +50 °C (32 °F to 122 °F)
-20° C to +65 °C (-4 °F to 149 °F)
IP code: IP 20
Weight: approx. 180g