stříkačkové filtry CHROMAFIL®, Polyvinylidenfluoride (PVDF)
Syringe filter CHROMAFIL®, Polyvinylidenfluoride (PVDF), Type non sterile , Filter diam. 25 mm, Pore size 1.0/0.45 µm, Housing PP-black/white
Výrobce
Zařazeno v kategoriích
Stříkačkové filtry
Popis
Syringe filter CHROMAFIL®, Polyvinylidenfluoride (PVDF)
CHROMAFIL® syringe filters are used for filtration of suspended matter from liquid samples. HPLC-Certification available on the internet
Polypropylene housing
Better solvent stability compared to acrylate and polystyrene filters
Shells ultrasonically sealed, not glued
No extractable components from glues
Filtration in both directions possible, the liquid cannot bypass the membranes
Luer lock on side of entry
Safe connection on the ''high pressure'' side
Luer exit
Standard luer for 3mm and 25mm filters, minispike luer with low dead volume and small OD for 15mm filters
Deflector
The stream of liquid is broken and distributed, and does not directly hit the membrane: this prevents rupture of the membrane
Star-shaped distribution device
The liquid is evenly distributed to the whole membrane surface: this results in a better utilisation of the total area; the filter is not rapidly clogged up; high flow efficiency
Colour coded
Filters with 0.2µm pores have a yellow upper housing, for filters with 0.45µm pores this is colourless; the different membrane types are distinguished by different colours
Low dead volume
~80µl for 25mm, 12µl for 15mm, 5µl for 3mm.
Specifications
The membrane housing consists of polypropylene (PP). This material is very resistant towards most solvents and has a very low extractable substances content. Thus it can be used with almost all solvents, acids and bases (see table). The especially thick rim of the housing is ideal for use with laboratory robots (e.g. Benchmateä). Filter inlet and filter outlet can be fitted to the CHROMABOND® columns for selective sample preparation with the aid of a special adaptor. All filters can be autoclaved at 121°C and 1.1bar for 30min.
ChromafiläXtra:
Labelled for method validation and certification. Colour-free plain polypropylene housing. Imprint for direct identification of the membrane type, diameter and pore size.
Hydrophilic membrane, for aqueous solutions, water-soluble oligomers and polymers like proteins binding capacity for proteins 20 µg/25 mm filter. The PVDF filter with integrated glass fibre prefilter (GF/P) is recommended for filtration of biological samples with high particle loads. This filter features a high binding capacity for proteins. Also suited for filtration of polar and non-polar solutions.
Type non sterile
Filter diam. 25 mm
Pore size 1.0/0.45 µm
Housing PP-black/white
CHROMAFIL® syringe filters are used for filtration of suspended matter from liquid samples. HPLC-Certification available on the internet
Polypropylene housing
Better solvent stability compared to acrylate and polystyrene filters
Shells ultrasonically sealed, not glued
No extractable components from glues
Filtration in both directions possible, the liquid cannot bypass the membranes
Luer lock on side of entry
Safe connection on the ''high pressure'' side
Luer exit
Standard luer for 3mm and 25mm filters, minispike luer with low dead volume and small OD for 15mm filters
Deflector
The stream of liquid is broken and distributed, and does not directly hit the membrane: this prevents rupture of the membrane
Star-shaped distribution device
The liquid is evenly distributed to the whole membrane surface: this results in a better utilisation of the total area; the filter is not rapidly clogged up; high flow efficiency
Colour coded
Filters with 0.2µm pores have a yellow upper housing, for filters with 0.45µm pores this is colourless; the different membrane types are distinguished by different colours
Low dead volume
~80µl for 25mm, 12µl for 15mm, 5µl for 3mm.
Specifications
The membrane housing consists of polypropylene (PP). This material is very resistant towards most solvents and has a very low extractable substances content. Thus it can be used with almost all solvents, acids and bases (see table). The especially thick rim of the housing is ideal for use with laboratory robots (e.g. Benchmateä). Filter inlet and filter outlet can be fitted to the CHROMABOND® columns for selective sample preparation with the aid of a special adaptor. All filters can be autoclaved at 121°C and 1.1bar for 30min.
ChromafiläXtra:
Labelled for method validation and certification. Colour-free plain polypropylene housing. Imprint for direct identification of the membrane type, diameter and pore size.
Hydrophilic membrane, for aqueous solutions, water-soluble oligomers and polymers like proteins binding capacity for proteins 20 µg/25 mm filter. The PVDF filter with integrated glass fibre prefilter (GF/P) is recommended for filtration of biological samples with high particle loads. This filter features a high binding capacity for proteins. Also suited for filtration of polar and non-polar solutions.
Type non sterile
Filter diam. 25 mm
Pore size 1.0/0.45 µm
Housing PP-black/white
Varianty produktu
Pro zobrazení cen na míru se přihlašte do klientské sekce.
Kód produktu
Kód produktu
Kód BDL 9049063 Kód výrobce 729219


Kód BDL 4003415 Kód výrobce
729219.4
Syringe filter CHROMAFIL®, Polyvinylidenfluoride (PVDF), Type non sterile , Filter diam. 25 mm, Pore size 0.45 µm, Housing PP-colourless/labelled
729219.4


Kód BDL 4003402 Kód výrobce
729039.4
Syringe filter CHROMAFIL®, Polyvinylidenfluoride (PVDF), Type non sterile , Filter diam. 25 mm, Pore size 1.0/0.45 µm, Housing PP-black/white
729039.4


Kód BDL 6287314 Kód výrobce
729244
Syringe filter CHROMAFIL®, Polyvinylidenfluoride (PVDF), Type non sterile , Filter diam. 13 mm, Pore size 0.45 µm, Housing PP-colourless/labelled
729244


Kód BDL 4003414 Kód výrobce
729218.4
Syringe filter CHROMAFIL®, Polyvinylidenfluoride (PVDF), Type non sterile , Filter diam. 25 mm, Pore size 0.20 µm, Housing PP-colourless/labelled
729218.4


Kód BDL 4003401 Kód výrobce
729039
Syringe filter CHROMAFIL®, Polyvinylidenfluoride (PVDF), Type non sterile , Filter diam. 25 mm, Pore size 1.0/0.45 µm, Housing PP-black/white
729039


Kód BDL 6287313 Kód výrobce
729243
Syringe filter CHROMAFIL®, Polyvinylidenfluoride (PVDF), Type non sterile , Filter diam. 13 mm, Pore size 0.20 µm, Housing PP-colourless/labelled
729243


Kód BDL 4003413 Kód výrobce
729218
Syringe filter CHROMAFIL®, Polyvinylidenfluoride (PVDF), Type non sterile , Filter diam. 25 mm, Pore size 0.20 µm, Housing PP-colourless/labelled
729218


Máte otázky? Kontaktujte nás