Gas analyzers MAT1400/MAT1500
Gas analyzers MAT1000 series are used for measuring oxygen concentrations (O2) or optional carbon dioxide concentrations (CO2).
Applies to all models of MAT1000 series:
-Easy and intuitive operation via touchscreen, even by untrained personnel
-Create your own method
-Available method parameters: scales, measurement procedures, limit values, comment and much more
-Selectable measurement methods: single or continuous
-Several single measurement procedures: manual, automatic, min/max detection
-Shortcut keys for most important functions
-Short measurement period, high accuracy even with small sample volume
-Validation possible
-Compliance with global standards such as GMP/GLP and 21 CFR Part 11
-Documentation of all measured values of the last 999 measurements
-Integrated interfaces, flexible data export (USB, Ethernet, RS-232)
-Compact design in robust cast aluminum housing
-Built-in air pressure sensor
-Integrated flow rate monitoring
Gas analysers for controlling protective gas packaging. The MAT1400 equipped with a zirconium dioxide sensor (ZrO2) measures the oxygen concentration over the entire measurement range between 0 and 100 vol% and with an excellent accuracy of ±0.001 vol%. The MAT1500 additionally features a non-dispersive infrared sensor for measuring carbon dioxide within the range of 0 and 50 vol% and with a high accuracy of ±0.5 vol%. Both devices are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside.

Measurement of O2 and CO2 e.g. in modified atmosphere packaging, for work with modified atmosphere conditions.
-For high sample throughput
-For high O2 concentration
-High precision with the lowest O2 concentrations
-Wide measurement range
-Drift-free zirconia sensor (ZrO2)
-Low-drift non-dispersive infrared sensor (NDIR), model MAT1500
-Environmental compensated CO2 measurement, model MAT1500
Specifications
O2 measuring range: 0 to 100 Vol.-%
Accuracy: 0.001 Vol.-% (<1 Vol.-%)
0.1 Vol.-% (<6 Vol.-%)
0.1 Vol.-% (<35 Vol.-%)
Resolution:
CO2 measuring range (only MAT1500): 0.001 Vol.-%
0 to 50 Vol.-%
Accuracy:
Resolution: ±0.5 Vol.-%
0.1 Vol.-%
Average measurement period:
Heating time: 5 to 10 sec
10 min
Interface: RS-232, USB, Ethernet
Dimensions (W x D x H): 200 x 350 x 150 mm
Weight: 4.6 kg
Power consumption: 60 W
Power supply: 100-250 V, 50/60 Hz

Type MAT1400
Description with zirconia sensor for oxygen

Varianty produktu

Kód produktu
Kód produktu
Kód BDL 6269837 Kód výrobce
MAT 1500
Type MAT1500 , Description with zirconia sensor for oxygen and NDIR carbon dioxide sensor
Skladovost
na dotaz
Cena bez DPH
238 448 Kč Pro registrované
226 526 Kč
Kód BDL 6269836 Kód výrobce
MAT 1400
Type MAT1400 , Description with zirconia sensor for oxygen
na dotaz
187 852 Kč Pro registrované
178 459 Kč