EC analytical columns NUCLEODUR® 100-5 NH2, 5µm
pore size 110 Å, particle sizes 3 and 5µm; 2,5%C; not endcapped - USP L8
multi-mode columns (RP and NP)
normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticides
reversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systems
ion exchange chromatography of anions and organic acids using common buffers and organic modifiers
stable against hydrolysis at low pH, working range pH 2-8, 100% stable in water, suitable for LC-MS
Ideal for:
polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditions
Eluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.
eluent in column n-heptane, particle size 5µm.
Int. diam. 4 mm
Length 125 mm
pore size 110 Å, particle sizes 3 and 5µm; 2,5%C; not endcapped - USP L8
multi-mode columns (RP and NP)
normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticides
reversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systems
ion exchange chromatography of anions and organic acids using common buffers and organic modifiers
stable against hydrolysis at low pH, working range pH 2-8, 100% stable in water, suitable for LC-MS
Ideal for:
polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditions
Eluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.
eluent in column n-heptane, particle size 5µm.
Int. diam. 4 mm
Length 125 mm
Varianty produktu
Pro zobrazení cen na míru se přihlašte do klientské sekce.
Kód produktu
Kód produktu
Kód BDL 4004537 Kód výrobce 760722.46 EC analytical columns NUCLEODUR® 100-5 NH2, 5µm, Int. diam. 4.6 mm, Length 250 mm
Kód BDL 4004534 Kód výrobce
760720.46 EC analytical columns NUCLEODUR® 100-5 NH2, 5µm, Int. diam. 4.6 mm, Length 125 mm
760720.46 EC analytical columns NUCLEODUR® 100-5 NH2, 5µm, Int. diam. 4.6 mm, Length 125 mm
Kód BDL 4004536 Kód výrobce
760722.4 EC analytical columns NUCLEODUR® 100-5 NH2, 5µm, Int. diam. 4 mm, Length 250 mm
760722.4 EC analytical columns NUCLEODUR® 100-5 NH2, 5µm, Int. diam. 4 mm, Length 250 mm
Kód BDL 4004533 Kód výrobce
760720.4 EC analytical columns NUCLEODUR® 100-5 NH2, 5µm, Int. diam. 4 mm, Length 125 mm
760720.4 EC analytical columns NUCLEODUR® 100-5 NH2, 5µm, Int. diam. 4 mm, Length 125 mm
Kód BDL 4004535 Kód výrobce
760721.46 EC analytical columns NUCLEODUR® 100-5 NH2, 5µm, Int. diam. 4.6 mm, Length 150 mm
760721.46 EC analytical columns NUCLEODUR® 100-5 NH2, 5µm, Int. diam. 4.6 mm, Length 150 mm
Máte otázky? Kontaktujte nás
Poslat