EC analytické kolony NUCLEOCEL DELTA-RP S, 5µm
EC analytical columns NUCLEOCEL DELTA-RP S, 5µm, Int. diam. 4.6 mm, Length 250 mm
Výrobce
Zařazeno v kategoriích
Kolony HPLC
Popis
EC analytical columns NUCLEOCEL DELTA-RP S, 5µm
NUCLEOCEL DELTA enantiomer separation based on cellulose derivatives
base material silica,
chiral selector Cellulosetris-(3,5-dimethylphenylcarbamate) - USP L40
similar phases: Chiralcel® OD, Kromasil®, CelluCoatä, Eurocel® 01
standard particle size 10µm
S-Type for high resolution, allows use of shorter columns (150 mm) for faster separations, pressure stability up to ~ 150 bar (2000 psi)
NUCLEOCEL DELTA for normal phase applications:
eluent in column n-heptane - propanol-2 (90:10, v/v)
typical eluents are heptane - propanol mixtures
NUCLEOCEL DELTA-RP for reversed phase applications:
eluent in column acetonitrile - water (40:60), v/v)
designed for use either in polar organic mode or with eluents containing high concentrations of chaotropic salts such as perchlorate
recommended applications: pharmaceutically active compounds, chiral pollutants (e. g. herbicides, PCB), chiral compounds in food (dyes, preservatives), chiral catalysts and bioorganic compounds.
Eluent in column acetonitrile - water, particle size 5µm.
Int. diam. 4.6 mm
Length 250 mm
NUCLEOCEL DELTA enantiomer separation based on cellulose derivatives
base material silica,
chiral selector Cellulosetris-(3,5-dimethylphenylcarbamate) - USP L40
similar phases: Chiralcel® OD, Kromasil®, CelluCoatä, Eurocel® 01
standard particle size 10µm
S-Type for high resolution, allows use of shorter columns (150 mm) for faster separations, pressure stability up to ~ 150 bar (2000 psi)
NUCLEOCEL DELTA for normal phase applications:
eluent in column n-heptane - propanol-2 (90:10, v/v)
typical eluents are heptane - propanol mixtures
NUCLEOCEL DELTA-RP for reversed phase applications:
eluent in column acetonitrile - water (40:60), v/v)
designed for use either in polar organic mode or with eluents containing high concentrations of chaotropic salts such as perchlorate
recommended applications: pharmaceutically active compounds, chiral pollutants (e. g. herbicides, PCB), chiral compounds in food (dyes, preservatives), chiral catalysts and bioorganic compounds.
Eluent in column acetonitrile - water, particle size 5µm.
Int. diam. 4.6 mm
Length 250 mm
Varianty produktu
Pro zobrazení cen na míru se přihlašte do klientské sekce.
Kód produktu
Kód produktu
Kód BDL 4002448 Kód výrobce 720450.46 EC analytical columns NUCLEOCEL DELTA-RP S, 5µm, Int. diam. 4.6 mm, Length 250 mm
Kód BDL 4002449 Kód výrobce
720451.46 EC analytical columns NUCLEOCEL DELTA-RP S, 5µm, Int. diam. 4.6 mm, Length 150 mm
720451.46 EC analytical columns NUCLEOCEL DELTA-RP S, 5µm, Int. diam. 4.6 mm, Length 150 mm
Máte otázky? Kontaktujte nás
Poslat